PUR/PIR with invisible clamps

PUR/PIR with invisible clamps 1

Thanks to invisible clamps system, sandwich panels with polyurethane and polyisocyanurate core make walls of industrial buildings look unique and a wide variety of profiles of panel cladding make each building look individual. A

wide range of varnish layer colours is also available. PUR/PIR core panels are of very good physiochemical properties and are resistant to humidity, fungus and mildew. Please contact us to receive a good offer.


PUR/PIR with invisible clamps 2

Insulating core properties:

  • PUR rigid polyurethane foam of thermal conductivity coefficient
    Lambda I = 0,022W/m*K, density 40 (+,-) 3kg/m3
  • PIR rigid polyurethane foam of thermal conductivity coefficient
    Lambda I = 0,020 W/m*K, density 40 (+,-) 3kg/m3 and increased fire-retardant parameters

Mechanical properties:


The panels are manufactured in conformity with PN-EN 14509:2010 norm and have the CE marking.
Thickness: 60mm 80mm 100mm 120mm
Modular width (mm) 1000 1000 1000 1000
1150 1150 1150 1150
Length (mm) min. 2000 mm
maks. 15 000 mm
min. 2000 mm
maks. 15 000 mm
min. 2000 mm
maks. 15 000 mm
min. 2000 mm
maks. 15 000 mm

Insulating properties [W/m2K] /*coefficient U may slightly differ depending on the manufacturer/

PUR* 0,37 0,27 0,22 0,18
PIR* 0,33 0,25 0,2 0,17

Fire spread /*may slightly differ depending on the manufacturer/

PUR* - - EI 15 EI 15
PIR* - - EI 30 EI 30
PUR reaction to fire B-s2,d0 B-s2,d0 B-s2,d0 B-s2,d0
PIR reaction to fire B-s2,d0 B-s2,d0 B-s2,d0 B-s2,d0
Fire spread NRO NRO NRO NRO

Acoustics/insulation coefficient

Rw [dB] 25 25 25 25
RA1 [dB] 23 23 23 23
RA2 [dB] 20 20 20 20
Sound absorption coefficient 0,15 0,15 0,15 0,15
Tightness
Air permeability Total tightness at pressure difference of -50/+50 Pa
Resistance to driving rain Class A – total tightness at 1200 Pa

Load bearing capacityć

Polyurethane sandwich panels bear wind, thermal and own load.

Deflections must not be larger than 1/200 span between the panel support - taking temporary load into consideration, and 1/100 – taking long-term load into consideration. Determined according to load and span tables, they are subject to linear interpolation.

The means of joining the plates to the supporting structure and the choice of mechanical connectors should be specified in building's technical design. The load per one connector (self-drilling screw) should not exceed 130 daN.