PUR/PIR with visible clamps

PUR/PIR with visible clamps 1

Both polyurethane and polyisocyanurate core panels are intended mainly for casing of industrial buildings, for refrigeration and food industry. They are also used as an excellent insulating material in general building industry.

PUR and PIR core is created in addition polymerization process. In polyurethane foam, the ratio of polyols to isocyanates is equal, whereas in PIR core the amount of isocyanates is increased at the cost of polyols. The addition of flame retardant makes PIR core far more resistant to fire than PUR. Therefore, PIR core wall panels are suitable for buildings that are subject to higher fire-retardant requirements. Please contact us to find out our competitive prices.

PUR/PIR with visible clamps 2

Insulating core properties:

  • PUR rigid polyisocyanurate foam of thermal conductivity coefficient
    Lambda I = 0,022W/m*K, density 40 (+,-) 3kg/m3
  • PIR rigid polyisocyanurate foam of thermal conductivity coefficient
    Lambda I = 0,020 W/m*K, density 40 (+,-) 3kg/m3 and increased fire-retardant parameters

Mechanical properties


The panels are manufactured in conformity with PN-EN 14509:2010 norm and have the CE marking.
Thickness: 40mm 60mm 80mm 100mm 120mm
Modular width (mm) - 1000 1000 1000 1000
1080 1080 1080 1080 1080
1150 1150 1150 1150 1150
Length min. 2000 mm
maks. 15 000 mm
min. 2000 mmmm
maks. 15 000 mm
min. 2000 mmmm
maks. 15 000 mm
min. 2000 mmmm
maks. 15 000 mm
min. 2000 mmmm
maks. 15 000 mm

Insulating properties [W/m2K] /*coefficient U may slightly differ depending on the manufacturer/

PUR* 0,54 0,36 0,27 0,22 0,18
PIR* 0,48 0,33 0,25 0,2 0,17

Fire parameters /*may slightly differ depending on the manufacturer/

PUR* - - - EI 15 EI 15
PIR* - - - EI 30 EI 30
PUR reaction to fire - B-s2,d0 B-s2,d0 B-s2,d0 B-s2,d0
PIR reaction to fire - B-s2,d0 B-s2,d0 B-s2,d0 B-s2,d0
Fire spread NRO NRO NRO NRO NRO

Acoustics/insulation coefficient

Rw [dB] 25 25 25 25 25
RA1 [dB] 23 23 23 23 23
RA2 [dB] 20 20 20 20 20
Sound absorption coefficient 0,15 0,15 0,15 0,15 0,15
Tightness
Air permeability Całkowita Total tightness at pressure difference of -50/+50 Pa
Resistance to driving rain Class A – total tightness at 1200 Pa

Load bearing capacity

Polyurethane sandwich wall panels bear wind, thermal and own load.

Deflections must not be larger than 1/200 span between the panel support - taking temporary load into consideration, and 1/100 – taking long-term load into consideration. Determined according to load and span tables, they are subject to linear interpolation.

The means of joining the plates to the supporting structure and the choice of mechanical connectors should be specified in building's technical design. The load per one connector (self-drilling screw) should not exceed 130 daN.